BS EN 50615 isn't mandatory in the UK; it's a product standard. Currently, nothing compels a building to have compliant devices installed.
However, what has changed is that BS 9991:2024 – the code of practice for fire safety in residential buildings – now references it explicitly[3]. The commentary to clause 5.6 observes that fitting cooking appliances with thermal cut-off devices – and it names BS EN 50615 as the specification for them – can reduce the risk of ignition.
This is narrower than it might sound. A commentary in a BSI standard merely explains the rules; it accompanies them, but it isn't one of them. That means BS 9991 doesn't say that a building should have these devices, and it doesn't oblige anyone to fit one. What it does is put the standard in front of people who design residential buildings – which is why BS EN 50615 has started appearing in fire strategies and specifications, and why many people are meeting it for the first time without much prior context.
Clause 5.6 Commentary of BS 9991:2024BS 9991:2024 · Clause 5.6 CommentaryApproved Document B, the statutory guidance supporting the Building Regulations in England, carries no mention of ignition prevention devices or BS EN 50615. It is currently under review.
Norway has been ahead of the curve for many years when it comes to preventing cooking fires. Stove guards have been required in new domestic installations, and wherever new wiring is run to the cooker, since 1 July 2010[4] – five years before this standard existed. The order of events is worth noting: the requirement came first, and the European test standard was only written afterwards for a class of device that was already being installed as a matter of routine in Norway.
The reason why this is significant is well-evidenced: cooking appliances are the largest single source of ignition in accidental dwelling fires in England, accounting for 44% of them[1]. Detection and suppression both act after ignition. This standard is the only one that describes a device capable of acting before a fire can start – in other words, this is genuine fire prevention.